During debugging, the dry running time of the pump shall not exceed 90 seconds. If it exceeds 90S, the pump motor may suffer insulation damage due to excessive dry running temperature. During daily use, the water level of the water source must not be lower than the pump inlet, and is generally required to be 30-50cm higher than the pump inlet. In order to prevent the water level from being lower than the pump inlet, a water level detection switch can be installed within 30-50cm above the pump inlet to detect the water level signal and transmit the signal to the solar controller in real time. When the water level is too low when the pump is running, the solar controller can cut off the power supply in time to protect the motor and avoid running dry without water.